This electrode angle corrector can quickly and accurately complete the stereotaxic positioning of the electrode at any angle, including right angle and compound angle.
MORE >
Electrode Zero Corrector (customized)
The electrode zero corrector is used to set the electrode during the experiment. In the vertical direction, the reference point is 30mm higher than the reference point of the ear bar. This product is specially designed for ZS-FD series brain stereotaxic instruments.
V-connector
This accessory can connect the fixing rod of the syringe pump from different manufacturers to the operating arm of the locator, which is convenient for the installation and use of these instruments, and the clamping range is about 8mm.
AP Micro Thruster - 50um
The accessory can be fine-tuned in the range of 25mm, in steps of 50um, front and rear. Through the knob, the manipulator arm can move more accurately back and forth on the guide rail of the MRI electromagnetic compatibility type, large animal or orbital small animal brain stereotaxic apparatus.
Rat and mouse head rotation platform
The height of the platform can be lifted up and down and rotated according to the specific experiment; the head immobilizer can be adjusted up and down in the vertical direction, and can be rotated 360 degrees in the horizontal direction, and the platform under the head immobilizer can be suspended, especially suitable for rats or Experiments in which the head and body of mice need to rotate 180 degrees during the operation, such as the cerebral ischemia modeling experiment by the suture method, real-time monitoring of blood flow changes in the animal's head (optical fiber fixed on the surface of the skull) to determine whether the modeling is successful.
Skull Level Alignment Holder
The craniofacial level calibrator refers to the international general brain map of rats (edited by Paxinos and Watson, 5th edition), with craniofacial Bregma and Lambda as reference points, corresponding to the centers of B(0) and L(0) respectively The distance is about 7.67mm. When the craniofacial of the animal is in a horizontal state, the two points should be on the same horizontal line. When fixed on the X-Z manipulator arm of the brain stereotaxic instrument, and the calibrator is gradually lowered, the tips of B(0) and L(0) should touch the cranial surface at the same time, if not, they should be adjusted by raising and lowering the animal head fixation adapter . After rotating the calibrator 180 degrees, the tip of B(2.25) is 2.25mm higher than the tip of L(0) when it is facing Bregma.
Syringe Holder
It is mainly used for micro-syringe administration experiments. It can fix the syringe barrel and needle at the same time, and the clamping of the syringe is more stable. The clamping range of the syringe barrel is 3mm-12mm, and the clamping range of the syringe needle is 0.3mm-1.5mm.
Headstage holder
With C-shaped design, it is open laterally, which is convenient for the placement of micro-amplifier or headgear (such as TBSI headgear, Plexon microelectrode amplifier), and the holder range is 0.1-7.0mm.