Features:
•8-inch color TFT display, resolution 800X600
• Adopt digital blood oxygen DSP algorithm, low perfusion, with excellent anti-exercise performance
• Animal-specific blood pressure algorithms that support measurement of various animal types
• Unique Chinese and English voice alarm
• Support USB data export, you can view the data directly on the computer
• Optional wired or wireless USB W legacy module connection to central monitoring system management software
•Optional anesthetic gas module, supports automatic measurement of 5 types of anesthetic gases
•Integrated module design to ensure monitoring stability and anti-interference ability
• Supports up to 12 channels of simultaneous waveform display
•Battery working time ≥ 4 hours
ECG ECG
Lead selection: 3/5 lead input
5-lead ECG: I, II, III, aVR, aVL, aVF, V
3-lead ECG: I, II, III
ECG channel: 7-lead ECG display on the same screen
Heart rate range: 15~300BPM
Gain selection: X1/4, X1/2, X1, X2
Scanning speed: 12.5/25/50 mm/s
Pacing detection function
Arrhythmia analysis function
3-channel ST segment analysis function
There are three modes of monitoring: surgical mode, monitoring mode, diagnosis mode
RESP breathing
Measurement method: impedance breathing
Respiratory lead: RA-LL chest lead impedance method
Waveform display speed: 6.25, 12.5, 25mm/s
Respiratory suffocation alarm function, 5-120 seconds
NIBP non-invasive blood pressure
Measurement method: automatic oscillometric method
Animal-specific blood pressure algorithms, supporting various animal types
Measurement unit: mmHg and Kpa display
Measurement parameters: systolic/diastolic/mean
Measurement method: manual/automatic/continuous measurement
Measuring range: Systolic blood pressure: 10 ~ 280mmHg
Diastolic blood pressure: 10~ 220mmHg
SPO2 blood oxygen saturation
Display mode: blood oxygen waveform and blood oxygen saturation value
Measurement parameters: blood oxygen saturation, pulse rate, pulse perfusion index
Measurement error: ±2% (70-100%)
Sensor type: Tongue clip animal blood oxygen probe
TEMP body temperature
Number of channels: 1
Measuring range: 0°C~50°C
Probe type: body surface probe or body cavity probe
Unit of measurement: Celsius
Resolution: 0.1℃
Error: ± 0.1 °C
EtC02 end-tidal carbon dioxide module
Mainstream/Sidestream optional
Measuring range: 0% ~ 13%
Resolution: 1 mmHg
Accuracy: ±2 mmHg (< 5.0% CO2, at standard atmospheric pressure)
Respiratory Rate: 3-150 bpm
This parameter is the basic parameter of the equipment, please contact our company for specific parameters