  • 小动物人工呼吸机.jpeg

Small animal artificial respirator


Ventilators are commonly used experimental equipment in medical laboratories. They are widely used in artificial respiration, respiratory management, animal first aid, and respiratory therapy in scientific research experiments such as basic medicine, clinical medicine, and animal medicine. Its control is accurate, convenient and practical, no high-pressure air source is required, the output of tidal volume is accurate, and the performance is stable.

Pre-consultation
Description Parameters Resources

Ventilators are commonly used experimental equipment in medical laboratories, and are widely used in artificial respiration, respiratory management, animal first aid, and respiratory therapy in scientific research experiments such as basic medicine, clinical medicine, and animal medicine. Its control is accurate, convenient and practical, no high-pressure air source is required, the output of tidal volume is accurate, and the performance is stable.
Features:                                                            
1. Using 5-inch LCD touch screen display and operation
2. With airway pressure and breathing waveform display function, with professional MADLAB graphic data analysis function
3. Automatic pressure relief protection when the airway pressure exceeds 6Kpa
4. With oxygen access port, it is convenient to access anesthetic gas or oxygen
5. With exhaust gas output port, easy access to anesthetic gas filter
6. Respiratory frequency adjustment range: 1 – 200 times/min
7. Output air volume calibration function: 1~80cc
8. Display LCD brightness adjustment: adjustable
9. Tidal volume adjustment range: 0.1-10ml
10. Adjustment of breathing ratio: 1:5~5:1
11. Suitable for mice, rats, guinea pigs and other animals
12. The equipment has a national registered trademark, has passed ISO9001 quality system certification, and has MADLAB computer software copyright

1. Instrument size: 335x260x100mm all-aluminum alloy body
2. Respiratory rate adjustment range: 1 – 200 beats/min
3. Tidal volume adjustment range: 0.1-10ml.
4. Adjustment of breathing ratio: 1:5~5:1
5. Airway pressure waveform display range: 7Kpa
6. Automatic pressure relief protection when the airway pressure exceeds 6Kpa
7. Ventilator interface specifications: diameter 6mm pagoda joint, material stainless steel
8. Output air volume calibration function: 1~80cc
9. Display LCD brightness adjustment: adjustable
10. Parameter display and operation: 5-inch touch LCD display
11. Screen resolution: 854x480
12. Input voltage: AC 110~220V/50Hz
13. Working environment temperature: 0 - 50℃
14. Relative humidity of working environment: <85%
15. Use air or other gas as the gas source, no need for high pressure gas, easy to use
16. Scope of application: suitable for mice, rats, guinea pigs and other animals
17. Endotracheal intubation: 14G, 15G, 16G, 18G, 20G, 22G, 25G seven specifications

Some published articles

1.Therapeutic hypothermia attenuates global cerebral reperfusion-induced mitochondrial damage by suppressing dynamin-related protein 1 activation and mitochondria-mediated apoptosis in a cardiac arrest rat model

2.Effect of ischemia on heart-type fatty acid binding protein expression in rat myocardium

3.Vitamin D/VDR regulates peripheral energy homeostasis via central renin-angiotensin system