Multifunctional anesthesia machine for large and small animals (double tank)
ZS-MV series large animal anesthesia machine is an anesthesia machine specially designed to provide isoflurane or sevoflurane and other anesthetics for cats, dogs, monkeys and pigs to perform inhalation anesthesia.
Pre-consultationZS-MV series large animal anesthesia machine is an anesthesia machine specially designed to provide isoflurane or sevoflurane and other anesthetics for cats, dogs, monkeys and pigs to perform inhalation anesthesia. The system consists of an anesthesia tank and a controller, which uses the air flow of the oxygen cylinder as power. Oxygen and isoflurane are mixed in the anesthesia tank and enter the animal through a mask or a ventilator. Short-term or long-term anesthesia control can be ensured. Precise depth of anesthesia and resuscitation within 2 minutes once anesthesia is over. Anesthesia techniques for laboratory animals have been widely used in biomedicine, clinical trial research and teaching experiments. Animal anesthesia is not only to reduce animal pain and meet the requirements of animal welfare, but also to ensure the smooth progress of animal surgery and experimental research. At present, injection anesthesia is the most common animal anesthesia in my country. The advantage is that no expensive equipment is required, just a syringe. However, after the anesthetic is injected into the animal, it must be metabolized by the liver before the animal wakes up; if the dose is too large, the animal will die from excessive anesthesia, and if the dose is too small, the animal cannot enter an anesthetized state or it is slow. In developed countries, gas inhalation anesthesia is very common in animal experiments, and various experimental animals such as rodents, dogs, and monkeys use gas inhalation anesthesia. The advantages of gas inhalation anesthesia are that animals enter anesthesia quickly, wake up quickly, easily control the depth of anesthesia, and have good safety. The morbidity and mortality of animals are low, the success rate of animal surgery is high, and its disadvantage is the need to add anesthesia.
Advantage
1. Using a single breathing circuit, no recirculation breathing system, reducing dead space.
2. Accurate glass tube oxygen flowmeter, precisely adjustable, suitable for low-flow anesthesia of small animals.
3. Select the classic Penlon anesthesia tank model isoflurane anesthesia vaporizer, with stable output, good airtightness, safety and reliability.
4. Precise design ensures accurate output concentration and is not affected by changes in flow, temperature, flow rate and pressure.
5. Precise scale adjustment to ensure the accuracy of the output
6. Safety locking device to prevent accidental volatilization of anesthetics
7. The large-view glass window is convenient for observing the degree of drug use
8. Simple medicine pouring device is convenient for users
9. Using the classic TECH3 anesthesia tank technology, the minimum anesthesia volatilization concentration is adjusted to 0.15%
10. The output concentration is not affected by changes in flow, pressure and temperature, and is accurate and reliable
11. Equipped with safety locking device to prevent accidental occurrence of anesthetic leakage and misuse of anesthetics
12. It adopts the classic Penlon anesthesia tank technology, and the minimum anesthesia volatilization concentration is adjusted to 0.15% to meet the different needs of customers
1. It is produced by a professional animal anesthesia machine manufacturer, with excellent product quality, stable performance, ISO9001 quality certification, specific national registered trademark, and national appearance patent certificate;
2. One set of equipment supports both open loop and closed loop anesthesia design, and provides independent access for both;
3. Provide a convenient mixed gas output port (Fresh gas outlet) for the open loop;
4. Provide independent air inlet Inhalation and air outlet Exhalation for closed loop;
5. Accurate glass tube oxygen flowmeter, the adjustment range is 0-4000ml/min, the step machine adjustment is 0.1ml, which is precisely adjustable, suitable for low-flow anesthesia of small animals; provide accurate oxygen flowmeter, display range: 0.2 to 4LPM ;
6. The ZS-MV animal anesthesia has a set of pipelines necessary for the open loop and closed loop; a special Pop-off valve is provided, which is connected to the exhaust gas recovery system on the one hand, and provides a continuous 2cmH2O negative pressure for the rebreathing air bag on the other hand. ;
7. With digital zoom function, observation is more clear and convenient (0-1800ml, 0-5000ml flowmeter can be selected);
8. It can be equipped with dual flowmeters as required, and you can choose nitrous oxide (N2O), nitrogen gas (N2), carbon dioxide gas (CO2), etc.;
9. Provide another breathing air bag for the closed loop, and provide continuous negative pressure by the Pop-off valve;
10. Flow range of anesthesia tank: 0~10L/min, oxygen flow: 0~4L/min, anesthetic concentration range: 0~5%, using the classic Penlon anesthesia tank technology, the minimum anesthesia volatilization concentration is adjusted to 0.15%, comes with Temperature, pressure, flow compensation function 200ml ~ 15L/min, anesthetic stock: 300ml
11. The structure is compact and beautiful; the built-in knob is easy to operate; the solid aluminum shell is adopted, and the surface is frosted, which is more convenient for scrubbing and disinfection;
12. The capacity of the absorption tank is not less than 900cc;
13. Equipped with a small animal anesthesia induction box, which can clearly observe the depth of anesthesia of anesthetized animals;
14. Provide an oxygen bypass switch so that oxygen can be directly conducted during animal pretreatment, instrument testing or any emergency; to ensure smooth operation and animal safety;
15. Pressure measurement range: 0-60cm H20;
16. Professional masks of various specifications: it can meet the needs of animals of different sizes, and there are several special masks (specially made) for rats and mice. The size of the mask can be tailored according to the size of the animal. Provide no less than 4 masks, and you can choose a variety of masks Components:
17. Exhaust gas absorption device: absorb part of the exhaust gas generated by open anesthesia to ensure the cleanliness of the experimental environment;
18. Large flow rate, high concentration, pure import, sieving, high oxygen concentration, when the flow rate is set to 1L, the concentration can reach 93%, which fully meets the oxygen content in the process of anesthesia for small animals;
19. Intelligent monitoring automatic alarm reminder, timed intelligent monitoring fault alarm, remote Bluetooth operation function, and prompting the cause of the fault;
20. Flow range of anesthesia tank: 0~10L/min, oxygen flow: 0~4L/min, anesthetic concentration range: 0~5%, minimum anesthesia volatilization concentration is adjusted to 0.15%, with temperature, pressure, flow compensation function , anesthetic stock: 250ml;
This parameter is the basic parameter of the equipment, please contact our company for specific parameters
Some published articles
1.Novel-graded traumatic brain injury model in rats induced by closed head impacts
2.Report on establishing hyperlipidemia model of SD rats in SPF grade
3. Effects of altitude changes on mild‑to‑moderate closed‑head injury in rats following acute high‑altitude exposure
4. Effects of risedronate sodium combined with simvastatin on tail suspension-induced bone loss in mice
5.Mechanism of L-lactate preconditioning improving neurological deficit in traumatic brain injury rats by enhancing GPR81 signaling pathway
For more literature, please consult: 400-016-4066
This parameter is the basic parameter of the equipment, please contact our company for specific parameters