Mouse rotating rod fatigue tester (new)
The rotating rod fatigue tester is an improved device based on similar foreign products and the rotating rod test device in Pharmacological Experimental Methodology. It has good practicality and is an ideal instrument for screening and identifying anti fatigue drugs. The instrument can be used for fatigue experiment, Motor coordination ability, skeletal muscle relaxation experiment, central nerve inhibition experiment, and other experiments that need to use exercise methods to detect the effect of drugs, such as the impact of toxicity on exercise ability, the impact of lack of certain substances in the body on exercise ability, the impact of cardiovascular and cerebrovascular drugs on exercise ability, etc. The basic principles and basic functions of the instrument can be developed and used in multiple directions.
Pre-consultationThe rotating rod fatigue tester is an improved device based on similar foreign products and the rotating rod test device in Pharmacological Experimental Methodology. It has good practicality and is an ideal instrument for screening and identifying anti fatigue drugs. The instrument can be used for fatigue experiment, Motor coordination ability, skeletal muscle relaxation experiment, central nerve inhibition experiment, and other experiments that need to use exercise methods to detect the effect of drugs, such as the impact of toxicity on exercise ability, the impact of lack of certain substances in the body on exercise ability, the impact of cardiovascular and cerebrovascular drugs on exercise ability, etc. The basic principles and basic functions of the instrument can be developed and used in multiple directions.
1. Mouse rotating rod diameter: 30mm
2. Mouse rotating rod length: 62mm
3. Number of mouse channels: 6 channels
4. Speed range: 1~60 rpm
5. Adjustment degree: 1 rpm
*6. Speed classification: Acceleration method: Multi stage acceleration (no upper limit)
7. First level acceleration time: 3-999 seconds
8. First level acceleration duration: 3-999 seconds
9. First level speed range: 1~60 meters
10. Second level acceleration time: 3-999 seconds
11. Second level acceleration duration: 3-999 seconds
12. Secondary speed range: 1~60 meters
13. N-level acceleration time: 3-999 seconds
14. N-level acceleration duration: 3-999 seconds
15. N-level speed range: 1~60 meters
16. With loop mode and forward reverse mode
17. The number of recording channels can be set: 1-6 channels
18. Experimental time range: 1 second to 999 minutes
19. Internal clock can operate for 10 years
20. Hourly error ≤ 0.0828 seconds
21. With USB interface, data can be imported into a USB drive
22. Internal storage:>500 sets of data
23. Operating environment temperature: 5 ℃ -40 ℃
24. Input voltage: 110-220V 50Hz
25. Automatic drop photoelectric recording
*26. Remote control: Yes
*27. WiFi ad hoc network technology, customized protocol stack, dedicated high-speed communication protocol
*28. High sensitivity sensor multi-channel collaborative collection
This parameter is the basic parameter of the equipment. Please contact our company for specific parameters