Animal experiment platform (independent channel)
The speed setting range of the small animal Treadmill in the single channel version (animal experiment treadmill) of Zoomlion Science and Technology small animal Treadmill is 1-100m/min, with an accuracy of 0.1m/min. Adopting segmented speed control, with higher degrees of freedom, it can adapt to different needs of experiments. The runway can automatically tilt at -25 to 25 degrees. The instrument can automatically detect running speed, distance, and relative distance. When aversive stimulation is required, animals can be electrocuted with a range of 0-2mA and an accuracy of 0.1mA., In the experiment, all electrical stimuli above 50ms will be recorded and saved with an accuracy of 1ms. Specially designed anti pinch power grid to reduce the situation of mice being pinched.
Pre-consultationThe speed setting range of the small animal Treadmill in the single channel version (animal experiment treadmill) of Zoomlion Science and Technology small animal Treadmill is 1-100m/min, with an accuracy of 0.1m/min. Adopting segmented speed control, with higher degrees of freedom, it can adapt to different needs of experiments. The runway can automatically tilt at -25 to 25 degrees. The instrument can automatically detect running speed, distance, and relative distance. When aversive stimulation is required, animals can be electrocuted with a range of 0-2mA and an accuracy of 0.1mA., In the experiment, all electrical stimuli above 50ms will be recorded and saved with an accuracy of 1ms. Specially designed anti pinch power grid to reduce the situation of mice being pinched.
1. Display method: 7-inch capacitive touch screen
2. Touch screen resolution: 800 * 480
3. Single channel Treadmill (mouse)
4. Single channel size: 564 * 57 * 70mm (length, width, height)
5. Overall appearance: 673 * 184 * 424mm
6. Single channel Treadmill (rat)
7. Single channel size: 564 * 90 * 150mm (length, width, height)
8. Overall appearance: 673 * 184 * 504mm
9. Single channel Treadmill (sealed)
10. Single channel size: 575 * 57 * 70mm (length, width, height)
11. Overall appearance: 807 * 184 * 458mm
12. Applicable animals: suitable for both large and small mice
13. Adjustable speed range: 0-80m/min
14. Speed accuracy: 0.1m/min
15. Speed setting method: segmented free setting
16. Each speed period: 0-9999 seconds
17. Acceleration time per segment: 0-9999 seconds
18. Experimental time range: 1 second~9999 minutes
19. Electric stimulation intensity range: 0.0-2.0mA
20. Electrical stimulation tolerance time: 0-999s, step size 0.1s
21. Electric stimulation recording accuracy: 1ms
22. Special power grid to prevent pinch injuries
23. Angle control accuracy: 1 degree
24. Angle control method: Program control, which can automatically run the angle according to the set running time
25. Angle control range: -25 degrees to 25 degrees
26. Angle acquisition method: Aviation geomagnetic sensors collect the current absolute angle and support zero point calibration
27. Minimum recorded electrical stimulation time: 50ms (i.e. recording electrical stimulation for more than 50ms)
28. The data storage adopts 15 sets of data cyclic coverage, which can continuously record the latest data
29. Export using USB flash drive
30. Collection indicators: total experimental time, total exercise distance, exhaustion time, number of shocks per channel, time of each shock, duration of each shock, speed at each shock, and exercise distance at each shock
31. Wireless control: Ad hoc network system, multi terminal control of computers and tablets, supporting systems above Windows 7, ubuntu, debian, centos and other mainstream Linux distributions.
32. Wireless control disconnection and reconnection function: In case of emergencies, the wireless control terminal has a disconnection and reconnection function to ensure the accuracy of experimental data.
This parameter is the basic parameter of the equipment. Please contact our company for specific parameters